| 21-3544 |
12301 |
ELMWOOD ST |
92840 |
Sep 15, 2021 |
|
Expired |
Residential |
Electric Service Panel Upgrade (Online) |
SERVICE PANEL UPGRADE. EDISON APPROVED RELOCATION FROM 60 AMP TO 225 AMP OVERHEAD 1 subpanels |
|
Raymond Serna |
$210.00
|
| 21-3543 |
8891 |
LARSON AVE |
92844 |
Sep 15, 2021 |
Oct 20, 2021 |
Finaled |
Residential |
Electric Service Panel Upgrade (Online) |
SERVICE PANEL UPGRADE. EDISON APPROVED RELOCATION FROM 225 AMP TO 200 AMP OVERHEAD |
|
SOUTHWEST SUN SOLAR, INC |
$215.00
|
| 21-3542 |
13271 |
PINTO RD |
92843 |
Sep 16, 2021 |
Apr 21, 2022 |
Finaled |
Residential |
Photovoltaic |
INSTALL (N) ROOF MOUNTED PVS 3.0KW AND (8) PANELS FOR MAIN HOUSE |
|
SUNPRO SOLAR INC |
$424.50
|
| 21-3541 |
10621 |
ALDERSON AVE |
92840 |
Sep 15, 2021 |
Oct 26, 2021 |
Finaled |
Residential |
Photovoltaic |
INSTALL (N) ROOF MOUNTED PVS 9.99KW AND (27) PANELS FOR MAIN HOUSE |
|
|
$424.50
|
| 21-3540 |
13412 |
JACKSON ST |
92844 |
Sep 15, 2021 |
Dec 15, 2021 |
Finaled |
Residential |
Photovoltaic |
INSTALL (N) ROOF MOUNTED PVS 2.925KW AND (9) PANELS AND UPGRADE SERVICE PANEL TO 125A(SR#2232840) FOR MAIN HOUSE |
|
SOUTHWEST SUN SOLAR |
$584.50
|
| 21-3539 |
12815 |
GLORIA ST |
92843 |
Sep 17, 2021 |
Dec 01, 2021 |
Finaled |
Residential |
Photovoltaic |
INSTALL (N) ROOF MOUNTED PVS 2.76KW AND (8) PANELS FOR ADU |
|
ECOSOLAR USA ELECTRICAL LLC |
$424.50
|
| 21-3537 |
11531 |
MAC NAB ST |
92841 |
Sep 15, 2021 |
Apr 19, 2022 |
Finaled |
Residential |
Demo (Code Enforcement) |
REF CASE# 186212. DEMO PERMIT TO INCLUDE: 1) DEMO/REMOVE PATIO ALONG NORTH WEST EXTERIOR OF MAIN DWELLING (CAP AND TERMINATE ANY/ALL ELECTRICAL) 2) DEMO/REMOVE PATIO ENCLOSURE/BEDROOM 3) DEMO/REMOVE OUTDOOR SINK/BASIN ALONG WEST OF MAIN DWELLING (CAP AND TERMINATE ANY PLUMBING LINES 4) RESTORE GARAGE TO APPROVED USE (CAP AND TERMINATE ANY/ALL ELECTRICAL) 5) RELOCATE STORAGE SHED LOCATED IN THE FAR NORTHERN SETBACK A MINIMUM OF 3 FEET FROM PROPERTY LINE |
$5,000.00 |
HOMAZ BUILDERS |
$196.79
|
| 21-3536 |
12345 |
EUCLID ST |
92840 |
Sep 15, 2021 |
|
Expired |
Residential |
Sign |
INSTALL (1)(N) ILLUMINATED CHANNEL LETTER SIGN W/ LOGO - AMVETS & LOGO |
$1,000.00 |
HEFFERNAN, MIKE |
$350.85
|
| 21-3535 |
12321 |
WESTMINSTER AVE |
92703 |
Sep 15, 2021 |
|
Expired |
Residential |
Sign |
INSTALL (1) NON-ILLUMINATED LETTER CHANEL SIGN - A EYELASH & BEAUTY |
|
MASSIVE CONSTRUCTION |
$187.90
|
| 21-3534 |
12566 |
VALLEY VIEW ST |
92845 |
Sep 15, 2021 |
|
Expired |
Commercial |
Sign |
INSTALL (1)(N) ILLUMINATED LETTER CHANNEL SIGN - TITANIUM HEALTHCARE W/ LOGO |
$1,250.00 |
ORANGE COUNTY SIGNS & LIGHTING INC |
$361.78
|
| 21-3533 |
9431 |
DAKOTA AVE |
92844 |
Sep 20, 2021 |
|
Expired |
Residential |
Remodel (Code Enforcement) |
REF CASE# 186394. (AFTER THE FACT) 1) OBTAIN A PERMIT FOR THE NEW WINDOWS THAT HAVE BEEN INSTALLED IN THE HOUSE, INCLUDING THE SLIDING GLASS DOOR THAT WAS ADDED TO THE MASTER BEDROOM. 2) OBTAIN A PERMIT FOR A WHOLE HOUSE REMODEL INCLUDING THE KITCHEN, BOTH BATHROOMS AND THE CAN LIGHTS INSTALLED IN THE CEILING. |
$5,000.00 |
|
$749.29
|
| 21-3532 |
7051 |
GARDEN GROVE BLVD |
92841 |
Sep 16, 2021 |
|
Expired |
Commercial |
Sign |
INSTALL (2)(N) ILLUMINATED CHANNEL LETTER SIGNS ON (E) CANOPY - SINCLAIR. INSTALL (2)(N) ILLUMINATED LOGO - DINO. INSTALL (1)(N) ILLUMINATED CHANNEL LETTER WALL SIGN WITH LOGO ON (E) STORE FRONT - SINCLAIR W/ DINO LOGO |
$7,500.00 |
SUPERIOR ELECTRICAL ADVERTISING INC |
$376.93
|
| 21-3531 |
10372 |
DEWEY DR |
92840 |
Sep 14, 2021 |
Nov 18, 2021 |
Finaled |
Residential |
Photovoltaic |
INSTALL (N) ROOF MOUNTED PVS 6.50KW AND (20) PANELS AND SUBPANEL 125A FOR ADU. 11/9/21 Revision to solar breaker was installed in the main service panel, no new Subpanel. Trench from ADU to main house. 2nd AC disconnect on the main house. |
|
SOUTHWEST SUN SOLAR |
$584.50
|
| 21-3530 |
13152 |
LILLY ST |
92843 |
Sep 15, 2021 |
Oct 18, 2021 |
Finaled |
Residential |
Photovoltaic |
REF CASE# 186958. INSTALL (N) ROOF MOUNTED PVS 4.08KW AND (12) PANELS, SUBPANEL 225A, AND 27KW ENERGY STORAGE FOR MAIN HOUSE |
|
TESLA ENERGY OPERATIONS, INC. |
$584.50
|
| 21-3529 |
9681 |
SUTHERLAND WAY |
92844 |
Sep 15, 2021 |
Feb 08, 2022 |
Finaled |
Residential |
Photovoltaic |
INSTALL (N) ROOF MOUNTED PVS 7.35KW AND (21) PANELS FOR MAIN HOUSE |
|
SUNRUN INSTALLATION SERVICES INC |
$424.50
|
| 21-3528 |
12581 |
JANET LN |
92840 |
Sep 15, 2021 |
Jul 06, 2022 |
Finaled |
Residential |
Photovoltaic |
INSTALL (N) ROOF MOUNTED PVS 3.50KW AND (10) PANELS TO EXISTING SYSTEM FOR MAIN HOUSE. 9/30/21 Revision to change inverter rating to 6000W on Planset. Updated SOW line. Updated single line diagram, conduit schedule and electrical calcs. 10/29/21 Revision to change inverter rating to 3800W. Updated SOW line. 12/28/21 Revision to change inverter rating to 3800W on Planset. Updated SOW line. Updated single line diagram, conduit schedule and electrical calcs |
|
SUNRUN INSTALLATION SERVICES INC |
$554.50
|
| 21-3527 |
11356 |
DESMOND ST |
92841 |
Sep 14, 2021 |
Nov 30, 2021 |
Finaled |
Residential |
Masonry Fences |
CODE CASE # 182815: ADD (N) 430 LINEAR FT BY 6 FT HIGH, L TYPE FOOING WITHIN THE PROPERTY. BLOCK WALL TO AREAS, 5 FT IN FRONT, 360 FT IN REAR BY CHANNEL, 65 FT WITH (9272 JOYZELLE) NEIGHBOR
|
$6,500.00 |
BUILTEK CONSTRUCTION & ENGINEERING |
$226.67
|
| 21-3526 |
12431 |
STRATHMORE DR |
92840 |
Sep 15, 2021 |
Apr 05, 2022 |
Finaled |
Residential |
Photovoltaic (Code Enforcement) |
REF CASE# 186986. INSTALL (N) ROOF MOUNTED PVS 6.04KW AND (17) PANELS AND UPGRADE SERVICE PANEL TO 200A(SR#3101535) FOR MAIN HOUSE. 1/10/22 Revision to modules layout |
|
N E R D POWER CA LLC |
$584.50
|
| 21-3525 |
11522 |
WEST ST |
92840 |
Sep 14, 2021 |
|
Expired |
Residential |
Garage/Shed |
CONSTRUCT (N) 800 SF DETACHED STORAGE |
$45,000.00 |
MODERN MUSE CONSTRUCTION |
$1,990.82
|
| 21-3524 |
9542 |
SHANNON AVE |
92841 |
Sep 14, 2021 |
Dec 21, 2021 |
Finaled |
Residential |
Photovoltaic |
INSTALL (N) ROOF MOUNTED PVS 6.00KW AND (15) PANELS TO EXISTING SYSTEM ON MAIN HOUSE |
|
SUN DYNAMICS LLC |
$424.50
|
| 21-3523 |
9338 |
MERIDIAN LN |
92841 |
Sep 15, 2021 |
Oct 01, 2021 |
Finaled |
Residential |
Photovoltaic |
INSTALL (N) ROOF MOUNTED PVS 7.20KW AND (20) PANELS FOR MAIN HOUSE |
|
ECOSOLAR USA ELECTRICAL LLC |
$424.50
|
| 21-3521 |
9835 |
CHAPMAN AVE |
92841 |
Sep 14, 2021 |
|
Expired |
Commercial |
Fire Alarm |
MODIFY (E) FIRE ALARM SYSTEM AND ADD (N) CELLULAR COMMUNICATOR - OCFA SR 295900 |
|
A D T COMMERCIAL LLC |
$50.00
|
| 21-3520 |
12311 |
EPSILON ST |
92840 |
Sep 16, 2021 |
Nov 24, 2021 |
Finaled |
Residential |
Garage/Shed |
DEMO (E) STORAGE. CONSTRUCT (N) 516 SF DETACHED WORKSHOP
|
$10,000.00 |
|
$810.91
|
| 21-3519 |
11821 |
FLAMINGO DR |
92841 |
Sep 14, 2021 |
|
Expired |
Residential |
Electric Service Panel Upgrade (Online) |
SERVICE PANEL UPGRADES. FROM 60 AMP TO 200 AMP OVERHEAD-
SR: 3122116 |
|
UNIQUE ELECTRIC SERVICES INC |
$215.00
|
| 21-3518 |
13942 |
LA BONITA AVE |
92843 |
Sep 14, 2021 |
May 20, 2022 |
Finaled |
Residential |
New Address |
ESTABLISH ADDRESS 13946 LA BONITA AVE FOR NEW SECOND UNIT |
|
|
$140.00
|
| 21-3517 |
11822 |
GILBERT ST |
92841 |
Sep 15, 2021 |
Jun 23, 2023 |
Finaled |
Commercial |
Fire Alarm |
MODIFY (E) FIRE ALARM SYSTEM. INSTALL (N) WEATHER PROOF SPEAKERS/STROBES AND RELOCATE (E) SPEAKER/STROBE IN OPTICAL SALES AREA - OCFA SR 295434 |
|
POST ALARM SYSTEMS |
$50.00
|
| 21-3516 |
12151 |
MOCKINGBIRD CT |
92840 |
Sep 14, 2021 |
Feb 04, 2022 |
Finaled |
Residential |
Photovoltaic |
INSTALL (N) ROOF MOUNTED PVS 4.08KW AND (12) PANELS AND 13.5KW ENERGY STORAGE FOR MAIN HOUSE |
|
TESLA ENERGY OPERATIONS, INC. |
$424.50
|
| 21-3515 |
14422 |
TAFT ST |
92843 |
Sep 14, 2021 |
May 09, 2023 |
Finaled |
Residential |
Photovoltaic |
INSTALL (N) ROOF MOUNTED PVS 4.20KW AND (12) PANELS FOR MAIN HOUSE |
|
SUNRUN INSTALLATION SERVICES INC |
$574.50
|
| 21-3514 |
8936 |
ACACIA AVE |
92841 |
Sep 14, 2021 |
Aug 15, 2022 |
Finaled |
Residential |
Photovoltaic |
INSTALL (N) ROOF MOUNTED PVS 4.08KW AND (12) PANELS FOR MAIN HOUSE |
|
TESLA ENERGY OPERATIONS, INC. |
$424.50
|
| 21-3513 |
12862 |
SUNGROVE ST |
92840 |
Sep 14, 2021 |
Sep 30, 2021 |
Finaled |
Residential |
Reroof (Online) |
T/O 1 LAYER REPAIR SHEATHING REROOF MAIN STRUCTURE, GARAGE W/ SYNTHETIC UNDERLAYMENT COMP SHINGLES 30 SQ 4/12 PITCH |
|
Jose Vazquez |
$293.51
|